Product Description :
INFI Air Bed (Bed Sore Prevention Air Mattress) is an easy, cheap and efficient solution to keep bed sores away from short-term patients. It is cost-effective, simple to operate and prevents as well as cures bed sores. Its therapy system reduces pressure effectively at the aching joints and facilitates the flow of oxygen to the body tissues, thereby providing relief to the skin. Its superior design prevents the development of bed sores.
About Bed Sores
Bed sores is a condition to those people who are bed ridden for an extended period of time and stay in one position for too long without shifting their weight. A person is likely to get a pressure ulcer if he uses a wheelchair or is confined to a bed, even for a short period of time (for example, after surgery or an injury) as the continuous pressure against the skin reduces blood supply to that particular area and the effected tissues dies. Bed sores cuts off the body’s blood circulation especially to the vulnerable areas of the body such as the back, elbow, ankles, heels, hips, and the tail bone. These areas are not well- padded enough by the body’s muscle or fat. Body tissues are deprived of nutrients and oxygen when the underlying body tissue and the skin are trapped between the bone and the surface such as a bed or a wheelchair, adequate blood flow is restricted causing irreversible damages to the skin which leads to the death of the body tissues.
Precautions
| Trouble shooting
- Keep
the electric pump of air mattress on for 23 hours and keep it off for 1
hour.
- Do
not use the air mattress near open flame or very near to a heater.
- Do
not smoke near the air mattress
- Keep
sharp objects away from the air mattress.
- Do
not stand on the air mattress. Maximum weight bearing capacity is 100 kgs
therefore the attendants should not sit on the air mattress as this will
cause the mattress to leak.
- Keep
the pump of the air mattress away from water/damp surfaces. Clean the
mattress with mild detergent if required.
Trouble
shooting : In case the pump of the air mattress does not get
switched on please check the fuse at the bottom of the pump of air mattress, if
burn replace with a new fuse of 1.5A/250V. If the pump is working but the
mattress is not inflating please check the connections and then check the air
mattress for leakage. If found punctured use the puncture kit provided with the
air mattress.
Features & Specifications :
- Mattress Bed sore prevention system
- Anti Decubitis air mattresses & pump system
- Maximum weight bearing capacity 100 kg
- Continuous usage for 12 hours then rest time one hour
- Size of Mattress : Length 6.5 feet x Width 2.5 feet (approx.)
- Mattress Bubble Size : Height 2.5 inches (approx. when inflated)
- Individually packed kit consists of mattress and pump
- Most comfortable to the patient
- 1 year manufacturer's warranty for manufacturing defects as per their policy
Legal Disclaimer: While we take extra efforts to ensure that the displayed product
information is correct, on occasion manufacturers may alter the product
specifications. Actual product packaging and materials may contain more and/or
different information than that shown on our web site. We insist/recommend that
you do not solely rely on the information presented and that you always read
labels, warnings, and directions before using or consuming a product. For more
information about any specific product, please contact the manufacturer.
|
Country of Origin |
Country |
India |
Manufacturer/Marketer/Packer/Importer Info |
Manufacturer/Importer/Marketer Details |
INFINITY MEDIQUIP INDIA PVT LTD
164, First Floor, Naharpur Village, Sector-7, Rohini, Delhi-85 Near New Bal Bharati School |